Meander delay line with two turns, protecting against ultrashort pulses
Download article in PDF format
Authors: Nosov A. V., Surovtsev R. S., Gazizov T. R., Zabolotskiy A. M.
Annotation: The ability of a meander line consisting of two turns to protect electronic equipment against ultrashort pulses is considered. The results of quasi-static simulation of the microstrip line in air are obtained. Attenuation of pulse amplitude more than 5 times is shown.
Keywords: meander line, protection, even and odd modes, ultrashort pulse